Chapter 3 Multiple Choice Questions
Methods of mass analysis
Quiz Content
*
not completed
.
The relationship between
m/z
and magnetic field
B
in a sector mass spectrometer is:
m/z
α
B
1/2
correct
incorrect
m/z
α
B
correct
incorrect
m/z
α
B
2
correct
incorrect
m/z
α
B
3
correct
incorrect
*
not completed
.
The main function of an electrostatic analyser in a double-focussing sector mass spectrometer is to:
increase sensitivity
correct
incorrect
increase resolving power
correct
incorrect
prevent damage to the magnet
correct
incorrect
increase scan speed
correct
incorrect
*
not completed
.
A quadrupole mass analyser separates ions of differing
m/z
values by scanning:
the DC voltage
correct
incorrect
the RF voltage
correct
incorrect
both the DC and RF voltages
correct
incorrect
the magnetic field
correct
incorrect
*
not completed
.
The relationship between
m/z
and time of flight
t
in a TOF mass spectrometer is:
m/z
α
t
2
correct
incorrect
m/z
α
t
correct
incorrect
m/z
α
t
1/2
correct
incorrect
m/z
α 1/
t
correct
incorrect
*
not completed
.
Which of the following statements about ion trap analysers is correct?
Ion traps are beam analysers
correct
incorrect
Single ion trap analysers are capable of tandem MS (MS/MS)
correct
incorrect
Ion trap analysers have very slow scan rates
correct
incorrect
Ion trap analysers require an ultra-high vacuum
correct
incorrect
*
not completed
.
The relationship between
m/z
and ion cyclotron frequency
f
c
in an FTICR mass spectrometer is:
m/z
α
f
c
correct
incorrect
m/z
α
f
c
2
correct
incorrect
m/z
α
f
c
1/2
correct
incorrect
m/z
α 1/
f
c
correct
incorrect
*
not completed
.
Orbitrap analysers measure
m/z
by:
detecting the oscillation of ions between electrodes
correct
incorrect
using a strong magnetic field to trap ions
correct
incorrect
deflecting ions onto an electron multiplier
correct
incorrect
recording the drift time f ion packets
correct
incorrect
*
not completed
.
The order of typical resolving power of the following mass analysers is (note: > means greater than):
quadrupole > time of flight > FTICR
correct
incorrect
time of flight > quadrupole > FTICR
correct
incorrect
FTICR > time of flight > quadrupole
correct
incorrect
time of flight > FTICR > quadrupole
correct
incorrect
*
not completed
.
The duty cycle of a mass spectrometer is:
equal to its scan rate
correct
incorrect
the amount of time ions take to travel from the source to the detector
correct
incorrect
the proportion of time (%) that the analyser spends actively collecting ions within the range of possible
m/z
values specified by the scan
correct
incorrect
the number of samples it can analyse per hour
correct
incorrect
*
not completed
.
The main advantage of reflectron TOF analysers over linear ToF analysers, of similar dimensions, is:
they are cheaper to manufacture
correct
incorrect
they have faster scan rates
correct
incorrect
they have an increased mass range
correct
incorrect
they have increased resolving power
correct
incorrect